PT2 - PT2 |
Back to the index Back to the top of index |
I | Y | |||||
Connections(7) | Position | Remark |
Y | Right | Output |
I | Left | Input |
Parameters(3) | Default | Remark |
T1 | 1 | |
T2 | 1 | |
Kp | 1 |
Function | Second order transferfunction y(s)/i(s) = (Kp) / (1+(T1+T2)s+(T1*T2)s^2) |
|
Special | T1*T2 <> 0 | |
Note | Use this block in the block diagram only, for electric circuit filters, see the section Filters/Circuit |
Status | Standard | |
Export of Embedded C Code | YES |
Select from | Components\Library\Control\ContinuousControllers |
![]() |
Back to the index Back to the top of index |