DCM - DC Machine

Back to the index
Back to the top of index

Connection Diagram:
A1 SHAFT
A2
F1
F2
M


Connections(6)PositionRemark
SHAFT Right Mechanical Shaft
M Bottom
F2 Left Stator electrical connection 2
F1 Left Stator electrical connection 1
A2 Left Armature electrical connection 2
A1 Left Armature electrical connection 1

Parameters(6)DefaultRemark
JM 2m Rotor inertia
LF 5m Field inductance
LA 5m Stator inductance
RF 0.07 Field resistance
Ra 0.07 Stator resistance
K 0.256 Machine constant

Function DC Machine

Status Standard

Select from Components\Library\ElectricalMachines\DC

See also
PermanentMagnet, PM_FEM, Series, Shunt,
Back to the index
Back to the top of index

Online Helpclick here to get to the online help