Connection Diagram:
IFC
DC
MINUS


Connections(18)PositionRemark
MINUS Right
IFC Top
DC Right

Parameters(6)DefaultRemark
Rseries 10m Cell series resistance
TimeDelay 1 Time delay of the Fuel Cell [s]
NumberOfCells 1 Number of series Cells
Inominal 500m Nominal current of the Fuel Cell [A]
Vnominal 0.75 Nominal Voltage of the Fuel cell
Eoc 1.2 Open circuit voltage default = 1.2

Function The Fuel Cell is modeled by the Nernst equation and is easy to parameterize. Only the Nernst voltage, nominal voltage and nominal current, as well as the series resistance of one cell has to be specified. The number of cells in series can be specified too.
Special The time delay of the transient response is limited to a minumum of 10*dt

Status Standard

Select from Components\Library\GreenEnergy\FuelCell