La - Armature Inductance

Back to the index
Back to the top of index

Connection Diagram:
FM
IM


Connections(3)PositionRemark
IM Bottom Magnetizing current
FM Top Input the magnetizing flux here

Parameters(1)DefaultRemark
La 50mH Armature inductance [Henry]

Function Division of the Armature flux by the armature inductance.
Note Input and output are multiplexed 2 phase signals. Use Signal2Vector to get the numerical values

Status Standard
Export of Embedded C Code YES

Select from Components\Library\ElectricalMachines\IRTF\DCMachine

See also
AlternativeDifferentiator, CommutatorSegments, Commutator_Current, Commutator_Voltage, Fr, Ra, Ura,
Back to the index